Symptoms

  • ATF test step "Open a New Form" on table change_request returns failure with summary "This step failed because a client-side Javascript error was detected on the page being tested. See the logs and screenshots on the test result for details."

  • Test log shows "ReferenceError: changeRequestDateMsg is not defined"

 

  • When manually navigating to change_request.do and viewing via Chrome Inspector, the same error appears, although it does not get flagged as an error:

 

Cause

Out of the box sys_ui_annotation record with sys_id 6a68f68387613200eb01ff0b84e3ec24 is missing, or has been modified.

Resolution

  • If the annotation is required, then it can be imported from a working instance, or the attached XML.
  • If the annotation is not required, then the Client Script "Hide Date Message if Empty" needs to be de-activated.

 

 