Notifications

5 views

Symptoms


Under the "Qualys Last Scan" column, the date has not been updated since upgrading to London

Release


London Patch 1 HF 2

Cause


Missing Host import map for the customized fields

Resolution


After reviewing the sn_sec_cmn_src_cmdb_map, it was seen that there was records on the development instance in the list that were missing in the production instance. The missing records where the ones that control populating the date on the Qualys scan. Importing the missing records from dev to prod, fixed the issue

 

Article Information

Last Updated:2018-10-31 12:45:12
Published:2018-10-31